Main Control Functions
1. Number of control channels: Supports a maximum of 96 outputs (32 lamp groups)
2. Number of phase controls: 32 phases
3. Number of signal group outputs: 16 lamp groups as standard, maximum 32 lamp groups
4. Multi-period timing: 32 time schedules, with 128 time intervals per schedule
5. Pedestrian crossing: Supports coordinated pedestrian crossing control on road sections and pedestrian adaptive control
6. Inductive control: Supports 32 logic detector inputs; supports a maximum of 128 network protocol detector inputs (video, radar, geomagnetic, etc.); supports single-lane dual-detector configuration
7. Manual control: Supports manual control, side-door manual control, wireless remote control or upper-level computer remote control to meet on-site duty requirements
8. Control switching: Supports switching between manual and automatic control, ensuring minimum safe time and no abrupt changes in equipment signal switching
9. Cableless coordinated control: Supported, with coordination control achieved by setting phase offset via GPS time synchronisation
10. Special signal control: Supports remote manual control and special signal control
11. Short-connected junctions: Supports configuration of short-connected junctions to enable independent control of dual junctions
12. Temporary plans: Supports temporary pre-configured plan configuration via the platform, enabling plan distribution and clearing
13. Variable lanes: Supports configuration and control of variable lanes, tidal lanes and ramp access schemes, operating independently of traffic light control signals
14. Waiting areas: Supports waiting area configuration
15. Default lamp colour configuration: Supports default lamp colour settings (all red, amber flash, lights off, red flash), with unenabled phases and unconfigured channels in a scheme operating at the default lamp colour
16. Special states: Supports special control of lamp colours during scheme operation, such as time-based prohibition functions (special states: all red, amber flash, lights off, red flash)
17. Countdown timers: Supports configuration of learning-type countdown timers, pulse-type countdown timers, 485 communication-type countdown timers, as well as national standard and baud rate settings for communication-type countdown timers
18. Time synchronisation functions: NTP time synchronisation; GPS time synchronisation; upper-level computer network time synchronisation; manual time synchronisation
19. Phase parameters: Supports independent configuration of phase parameters for cycle plans and repeated phases, with different phase parameters used for each cycle plan
20. Signal control duration: Supports adjustable signal control duration
21. Automatic phase duration allocation: When adjusting the cycle, only the total cycle duration of the plan needs to be set, and each phase automatically allocates time based on the green split
22. Fault monitoring: Slow conflict monitoring and degradation mechanism; lamp monitoring fault degradation mechanism; fault software amber flash control; independent hardware amber flash control; fault information upload and query
23. Access control monitoring: Supports door opening/closing access control monitoring and reporting
24. Networked control: Supports communication and interaction with the upper-level computer, including temporary plans and special task operations
25. Information security: Supports identity authentication, control command verification, operation parameter update verification, and broadcast storm protection functions
26. Parameter configuration: Supports control parameter configuration via PC client and remote server
27. Lighting system: Supports door opening/closing linked lighting
28. Voltage display: Supports input voltage monitoring and display
29. Automatic maintenance: Supported
30. Control switches: 1 main power switch; 1 controller switch; 1 amber flasher switch; 1 socket switch (with 1 three-core socket and 1 two-core socket); 1 lighting switch; 4 spare switches
31. Power input: 1 main power input; 1 emergency power input (supports main/backup power knob switchover)
32. Network interfaces: 3 × 10/100M electrical ports; 1 WAN, 2 LAN
33. RS-232 interfaces: 4
34. RS-485 interfaces: 4
35. TF card interface: 1
36. GPS interface: 1, with a GPS antenna as standard